>
AP PGECET 2026
List of top Questions asked in AP PGECET- 2026
The "Hunting" in synchronous machines can be prevented by using:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Synchronous Motors
A 4-pole, 50 Hz induction motor has a synchronous speed of:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Induction Motor
If the air gap of an induction motor is increased, then,
AP PGECET - 2026
AP PGECET
Electrical Engineering
Induction Motor
The starting torque of a capacitor-start single-phase induction motor is:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Induction Motor
A synchronous motor can be used for power factor correction when it is:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Synchronous Motors
A 200/100 V transformer has a primary resistance of 0.1 $\Omega$. What is this resistance when referred to the secondary side?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Transformers
For two three-phase transformers to operate in parallel, which of these is an absolute requirement?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Transformers
In a DC Machine, the function of the commutator is to:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical Machines
The effect of "Armature Reaction" in a DC generator mainly results in:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Generator Parameters
An auto-transformer is most efficient when the transformation ratio ($K = V_2/V_1$) is:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Transformers
A symmetrical 3-phase fault occurs at a bus. If the pre-fault voltage is 1.0pu and the Thevenin impedance is j0.2pu, the fault current in per-unit is:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Fault Analysis
The "Corona Effect" in a transmission line is most likely to occur during
AP PGECET - 2026
AP PGECET
Electrical Engineering
Transmission Lines
If a transmission line carries 100 MW at unity power factor, the reactive power is:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical power
In a single-phase transformer, the core is laminated primarily to reduce:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Transformers
Which relay is most affected by power swings?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Fault Analysis
In Economic Load Dispatch, the most efficient operation occurs when:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical power
What is the primary purpose of a FACTS device like a STATCOM?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical power
HVDC transmission is preferred over HVAC for very long distances because:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical power
The Differential protection is primarily used for:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Fault Analysis
If the supply frequency increases, the Skin Effect in a conductor:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Current Distribution
A 100 MVA, 11 kV generator has a reactance of 0.2 pu. What is the reactance in ohms?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Generator Parameters
The "Equal Area Criterion" is used to determine:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Power System Stability
In a Load Flow study, which parameters are known at a PQ (Load) bus?
AP PGECET - 2026
AP PGECET
Electrical Engineering
Electrical power
The Swing Equation describes the relationship between:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Power System Stability
The Maximum power transfer in an AC network occurs when:
AP PGECET - 2026
AP PGECET
Electrical Engineering
Network Theorems
Prev
1
...
5
6
7
8
9
...
20
Next