>
TS PGECET
List of top Questions asked in TS PGECET
Accuracy in measurement relates to:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
Which of the following statements is true?
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
Which of the following is satisfied by a linear system?
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
In an 8-bit microcontroller, if the program counter is 16-bit wide, then the maximum addressable memory space is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
Which of the following statements is true?
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
CPU utilization in polling-based I/O is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
Signal conditioning is required mainly to:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
In a \(16\text{k} \times 8\) microprocessor, the number of address and data lines respectively are:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Analog and Digital Electronics
A 24 MHz microcontroller executes one instruction per clock cycle. If an interrupt service routine consumes 120 cycles, then the time taken by the ISR to execute is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
An SAR type ADC and a Flash type ADC have identical resolution and reference voltage. If both of them have same input signal bandwidth and sampling rate, then which of the following statements is true?
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
The output voltage of a 6-bit ladder type DAC with a digital input of 111001 is (Assume maximum output voltage is 10 V):
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
Increasing the resolution of an ideal N-bit ADC at constant reference voltage will:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
In ECG analysis, QRS detection is important because it represents:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
Discrete-time LTI system is BIBO stable if:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
For a clock frequency of 20 MHz, the output frequency of a flip-flop is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
In the ideal case, what is the input impedance of an operational amplifier?
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
If the outputs of XNOR and XOR gates with inputs a, b are connected to an AND gate, then the output is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
The transfer function of an LTI system is defined as:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
At very high frequencies, MOSFET is preferred because of:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
In an operational amplifier, slew rate limitation affects:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
If admittance of a circuit is \( Y = 0.3 - j0.4\text{ s} \), then the magnitude of the impedance is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Electrical Circuits
A signal that exists only for a finite duration of time is called:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
For an active low-pass filter of first order, the roll-off is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Signals and Systems
Consider the following statements:
Assertion (A): Norton current is equal to the short-circuit current at the output terminals.
Reason (R): Because Norton equivalent resistance is obtained by deactivating all independent sources and calculating the resistance seen from the output terminals.
The correct answer is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Electrical Circuits
If a circuit has unity power factor, then reactive power is:
TS PGECET - 2026
TS PGECET
Biomedical Engineering
Electrical Circuits
Prev
1
...
31
32
33
34
35
...
133
Next